표 1. | Table 1. 시험 항목별 적용 국제 표준 및 시험 조건 | International standards and test conditions applied per test item.

Test item Applied standard Frequency band Test level Modulation Dwell
Conducted immunity (BCI) ISO 11452-4 0.1∼400 MHz 200 mA (envelope) CW, AM (1 kHz, 80 %) 2s
Radiated immunity, ALSE (component) ISO 11452-2 20 MHz∼6 GHz 100 V/m CW, AM, PM 2s
Radiated immunity, ALSE (vehicle) ISO 11451-2 20 MHz∼2 GHz 30 V/m (distance 2 m) AM, PM 2s
Transient immunity (supply lines) ISO 7637-2 Pulse 1, 2a, 2b, 3a, 3b, 5b −150 to +100V Time-domain pulse -
Transient immunity (signal lines) ISO 7637-3 Pulse a, b/2a −110 to +75 V/±6 V Time-domain pulse -
Electrostatic discharge (ESD) IEC 61000-4-2, ISO 10605 - Contact: ±4 kV Air: ±2, 4, 8 kV 150 pF/330 Ω -
Radiated emission (RE) CISPR 25, ECE R10 30 MHz∼1 GHz Peak, quasi-peak RBW 120 kHz -