표 3. | Table 3. ICNIRP 1998 Guidelines과 2010 Guidelines의 주요 차이점 | Major differences between ICNIRP Guidelines of 1998 and 2010.

Item Guide lines Main differences
Basic restrictions 1998 - Induced current density in the body
2010 - Induced electric field strength in the body
Considered effects of the body 1998 - Prevent effects on nervous system functions.
- Threshold for induced current density in central nervous system(It is not considered phosphene.).
2010 - Used the threshold of phosphene for basic limiting exposure.
- Included with effects on the central and the peripheral nervous tissues.
- Internal electric fields were derived the conductivity of each tissue by anatomical models.
Reference levels 1998 - Used dosimetry quantities based on simple geometry models.
2010 - Used dosimetry quantities based on anatomically specific body models.
Contact currents 1998 Avoid shock and burn hazards.
- Reference levels for public is half of that for occupational(Considered threshold contact currents that elicit biological responses in children are one-half of that for adult men.).
- Object is to prevent from painful shock.
2010 - Equal guide lines 1998’s.