표 1. | Table 1. 측정된 두 위상잡음 차이 | Difference between two measured phase noises.

fm Mean difference (dB) E5052B uncertainty
10∼100 kHz 0.53 2 dB
100 kHz∼1 MHz −0.075
1∼10 MHz −0.83
Mean −0.2