표 1. | Table 1. 측정된 두 위상잡음 차이 | Difference between two measured phase noises.
f
m
Mean difference (dB)
E5052B uncertainty
10∼100 kHz
0.53
2 dB
100 kHz∼1 MHz
−0.075
1∼10 MHz
−0.83
Mean
−0.2