표 2. | Table 2. ICNIRP의 인체 내부 전기장, SAR 및 전류밀도 기본제한치(f=100 kHz~10 MHz) | Basic restrictions for internal field, current density and SAR by ICNIRP.

Category Occupational exposer Public exposer
Human internal electric field [V/m][15] 2.7×10−4f 1.35×10−4f
Current density(RMS)[14][mA/m2] f/100 f/500
SAR[14] [W/kg] Whole body average 0.4 0.08
Local(10 g-SAR) 10 2